Tie-back sheet pile quay wall – anchored bulkhead design
Design an anchored (tie-back) steel sheet pile quay wall to EN 1997-1 Design Approach 1 and EN 1993-5: embedment by free earth support, tie force, bending moment, shear and deflection, sheet pile, tie rod or F-T strand, wale and anchorage, with surcharge, crane and mooring loads and an EN 1998-5 seismic case.
Calculation method
EN 1997-1 Design Approach 1 (Combinations 1 and 2) with earth pressure coefficients from Annex C.2, net water pressure as a permanent action, unplanned excavation ΔH (9.3.2.2) and a 30 kPa default surcharge. Surcharge (general cargo), crane (front and rear rail, vertical and horizontal) and mooring (Fx spread over the bollard spacing) each lead in turn, with ψ0 on the others; partial and combination factors from BS 6349-1-2 Table 1 (Set B for C1, Set C for C2). Net pressure, shear and moment are shown for C1 and C2, the deflection for the SLS characteristic combination. Embedment by free earth support for every combination; tie force, shear, bending moment and deflection along the wall, with ordinary and seismic results on one chart. Sheet pile resistance to EN 1993-5 (class, βB, shear and axial interaction), or steel pipe sheet piles (SPSP, 132 sizes, P-T / P-P / L-T joints) with the class 4 bending resistance of EN 1993-5 Annex D, tie bar Ft,Rd or F-T strand to EN 1993-1-11, wale bending; anchoring wall, anchoring sheet pile or pile, or coupled batter piles; recommended spacing between the front wall and the anchor from the active and passive wedges. Optional rock mound behind the wall (trial wedge) and EN 1998-5 seismic case (Mononobe–Okabe, Westergaard).
About
Free online calculator by My Formulas, a reference for design and education. Enter the inputs, get the results at once, and open the step-by-step calculation (free member account) to check every value. Verify results independently before use.